PRODUCT

Normal TDS Membrane TW-1812-100


工件2.jpg


tit.png 1. Testing Condition and Performance


ModelPressure psi(bar)Permeate Flow GPD(L/H)Stable Rejection(%)
TW-1812-10070(4.8)100(15.77)97


a. The flow and rejection are based on following testing condition: 500ppm softened tap water、temperature 25°C、pH7.5-8、recovery rate 35% and above testing pressure 

b. The minimum rejection is 96.0%。

c. One single membrane flow may fluctuate within±20%


tit.png 2. Membrane Size

image.png

Model inch(mm)ABCDE
TW-1812-10011.74(298)0.875(22.2)0.68(17)
1.83(43±0.5)9.37(238)


tit.png 3. Operation Limits and Condition


Operation LimitsMembrane typePolyamide composite membrane
Maximum feed water temperature45℃
Maximum operating pressure300psi(20.68bar)
pH Range2-11
Maximum feed water SDI155
Maximum influent turbidity/NTU1
Free chlorine tolerance(mg/L)0.1


tit.png 4. Notice

(1) The first 5 gallons of produced water must be discarded. This initial stage of produced water is not drinkable, nor can it be used as cooking water.

(2) After the initial wetting, the components need to be kept in a wet state forever.

(3) When the system is out of service for a long time, it is recommended to immerse the membrane element in the preservation solution to prevent the growth of microorganisms in the system. Before using again, wash off the preservation solution.

(4) The membrane element still has some tolerance for short-term exposure to chlorine (hypochlorite). However, continuous contact may cause damage to the membrane element, so the above situation should be avoided.